Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Life (Basel) ; 13(5)2023 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-37240780

RESUMO

Gaucher disease (GD) is one of the most common lysosomal storage disorders. Bone complications are the most critical irreversible consequence of GD. Osteonecrosis (ON) of the femoral head inevitably leads to osteoarthritis and may be managed by hip arthroplasty. The introduction and worldwide use of therapeutic agents (specifically enzyme replacement therapies (ERT)) lowered the prevalence of osteonecrosis events per patient. We present the cases of two female patients who sustained simultaneous bilateral femoral head osteonecrosis after receiving ERT for long periods while exposed to concomitant risk factors related to femoral head ON. Both patients suffered severe pain and deterioration of their daily activity capabilities, and thus, were offered bilateral hip arthroplasty. Surgery was performed in both hip joints during the same procedure. The current report highlights several key aspects of femoral head ON in young patients with GD.

2.
J Clin Orthop Trauma ; 11(Suppl 2): S187-S191, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32189937

RESUMO

BACKGROUND: Venous thromboembolism (VTE) (Deep vein thrombosis (DVT), and pulmonary embolism (PE)), is a common complication in patients undergoing total joint arthroplasty (TJA). Recently, aspirin was recommended by the American Academy of Orthopaedic Surgeons (AAOS) as VTE prophylaxis following TJA. This study investigates VTE rates in TJA patients using as thromboprophylaxis. METHODS: DVT was screened for in 396 consecutive total hip or knee arthroplasty procedures. Patients were treated with early mobilisation, calf compression device and 300 mg aspirin for 5 days and then 100 mg aspirin for 5 weeks. All patients received lower-limb duplex ultrasonography prior to discharge. Patients were clinically evaluated at 6 weeks post-op documenting any VTE. RESULTS: 51 TJA's (12.87%) were complicated by VTE: one proximal, 47 distal DVT and 3 PE. No fatal PE occurred. Only four DVT were symptomatic. Of 159 THA, 2 (1.25%) had VTE: one distal DVT and one PE. Of 237 TKA, 49 (20.67%) had VTE: 1 proximal, 46 distal DVT and 2 PE. Patients with a history of diabetes and those receiving TKA were at higher risk of DVT. CONCLUSION: Multimodal VTE prophylaxis demonstrated a low rate of proximal DVT, PE and bleeding complications. The rate of asymptomatic DVT was high, but most were distal and unlikely to be clinically significant. Patients with diabetes and those receiving TKA could be at higher risk of asymptomatic DVT, and may benefit from closer clinical assessment. These findings suggest aspirin is safe and efficacious when used in combination with mechanical compressors and early mobilisation. However, our findings require further validation, particularly with larger, prospective comparative studies.

3.
Hip Int ; 30(3): 296-302, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-30924374

RESUMO

BACKGROUND: Offset and leg length (LL) restoration are critical for the achievement of a stable, well-functioning hip following total hip arthroplasty (THA). Several techniques are described in the literature, including a hip calibration gauge. We question whether meticulous preoperative planning of a specific surgical technique in combination with the utilisation of a calibration gauge can provide an accurate offset and LL restoration. METHODS: Retrospective review of 101 unilateral THAs via a posterior approach by a single surgeon. Preoperative radiographic LL and offset were radiographically calculated. Intraoperatively prior to hip dislocation a calibration gauge was used to measure LL and offset with a pin inserted into the iliac crest acting as a static referencing point. All had pelvis x-ray performed 6 weeks postoperatively. A literature review was conducted to establish average postoperative LL/offset values for statistical comparison. RESULTS: The average absolute postoperative leg-length discrepancy (LLD) was 2.51 mm compared to preoperatively 3.54 mm (p = 0.018). A total of 93.1% and 100% had LLD of ⩽5 mm and ⩽10 mm, respectively. The mean postoperative offset difference was 2.39 mm. The investigated LLD and offset results were comparable with literature data of studies utilising an intraoperative measuring device. LLD was significantly decreased when compared to a free-hand technique (LLD 4.42 mm, p < 0.001). CONCLUSION: The technique utilising preoperative templating, intraoperative offset verification together with the use of hip calibration gauge yielded accurate LLD and offset restoration as in the literature. Precise offset restoration, which often is a neglected issue, can lead to better abductor vector restoration, hip function and less pain.


Assuntos
Artroplastia de Quadril/métodos , Fêmur/cirurgia , Luxação do Quadril/cirurgia , Desigualdade de Membros Inferiores/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Calibragem , Feminino , Fêmur/diagnóstico por imagem , Luxação do Quadril/complicações , Luxação do Quadril/diagnóstico , Humanos , Período Intraoperatório , Desigualdade de Membros Inferiores/diagnóstico , Desigualdade de Membros Inferiores/etiologia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Radiografia , Estudos Retrospectivos
4.
J Arthroplasty ; 33(4): 1210-1214, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29246719

RESUMO

BACKGROUND: Squeaking is an on-going complication with a variable incidence of 0.5%-20.7%. The mechanism of squeaking has not been understood completely and is most likely multifactorial in nature. Previously, we have reported on a squeaking rate of 7.3% at 2 years. Our current results show a substantial increase in the squeaking incidence from 7.3% to 17.4% with the DeltaMotion articulation at the 5-year follow-up. METHODS: Two hundred six total hip arthroplasties with a large ceramic-on-ceramic bearing were performed on 195 patients by 2 senior authors. The minimum duration of follow-up was 5 years (range 5-6.2). RESULTS: The mean Harris Hip Score remained stable at 91.7 at 5 years compared to 92 after 2 years. However, we observed an increase in the squeaking rate from 7.3% after 2 years to 17.4% after 5 years. As in previous studies, we did not find significant differences between the silent and squeaking group in relation to age, height, weight, and femoral head diameter. In contrast, others reported no significant differences regarding range of motion and gender between the silent and the squeaking hip group at 2 years of follow-up, whereas at 5 years, the squeaking group showed a significantly higher combined range of motion and a higher relative risk of squeaking in women compared to the silent group. CONCLUSION: While large diameter ceramic bearings may produce squeaking, especially in female patients, our mid-term clinical results of a large ceramic-on-ceramic bearing in total hip arthroplasty are encouraging. Nevertheless, long-term follow-up is recommended.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cerâmica , Prótese de Quadril , Desenho de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Cabeça do Fêmur , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Amplitude de Movimento Articular , Índice de Gravidade de Doença , Fatores Sexuais , Som
5.
J Orthop Sci ; 22(1): 116-120, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27823847

RESUMO

INTRODUCTION: The technical objective of total knee arthroplasty (TKA) is to restore normal mechanical parameters to the knee. Patient-specific instrumentation (PSI) was developed to streamline the operative process and improve accuracy. PSI produces individualized cutting guides based on three-dimensional models of the patient's anatomy acquired from computed-tomography (CT) or magnetic-resonance imaging (MRI). However, the superiority of one modality over the other remains unclear. Therefore, we aimed to compare the accuracy of patient-specific cutting guides produced from MRI or CT imaging methods in TKA. METHODS: Electronic databases were systematically searched using relevant keywords and MeSH terms for original-data English-language publications comparing the accuracy of CT and MRI-based PSI cutting guides in TKA. Data was extracted from the text, tables and figures of studies and meta-analysed. RESULTS: MRI-based PSI cutting guides produced a lower proportion of coronal plane outliers (>3°) with regard to overall limb mechanical axis (OR 2.75, p = 0.01). There were no significant differences between the two in terms of sagittal femoral and tibial component placement, or coronal femoral and tibial placement, or femoral component axial rotation. Tibial rotation was not analysed in the literature. CONCLUSIONS: MRI-based patient-specific cutting guides produced a lower proportion of outliers in the overall coronal alignment of the limb compared to CT, with no significant difference between the two in terms of femoral or tibial component placement. Future studies should investigate the differences in resource usage and operative time between the two to inform surgeons' decision making when choosing an ideal imaging modality for PSI TKA. STUDY DESIGN: Meta-analysis. LEVEL OF EVIDENCE: III, systematic review of cohort and comparative studies.


Assuntos
Artroplastia do Joelho/instrumentação , Imageamento por Ressonância Magnética/métodos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Artroplastia do Joelho/métodos , Mau Alinhamento Ósseo/prevenção & controle , Feminino , Fêmur/cirurgia , Seguimentos , Humanos , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Recuperação de Função Fisiológica/fisiologia , Medição de Risco , Tíbia/cirurgia , Resultado do Tratamento
6.
Knee Surg Sports Traumatol Arthrosc ; 25(6): 1678-1685, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27492384

RESUMO

PURPOSE: In patient-specifically instrumented (PSI) total knee arthroplasty, the correlation between the pre-operative surgical plan, accuracy of the cutting block, and intra-operative resection size is unclear. The aim of this study was to evaluate the ability to accurately execute the PSI surgical plan and to add to the merging information with respect to this technology with the hypothesis that the PSI blocks would demonstrate good accuracy with regard to the bony thickness of the resections. METHODS: One hundred and thirty TKAs using PSI (MRI/long-leg radiographs) were retrospectively analysed. All surgeries were conducted via similar surgical approach and technique, with resection performed after guide placement and alignment assessment. The bony cut thicknesses of the medial (MTP) and lateral tibial plateau (LTP), distal medial (DM), distal lateral (DL), posterior medial (PM) and posterior lateral (PL) femur were measured with a vernier calliper. The measured resection thickness was subtracted from the planned resection. Errors were defined as ≤1.5 mm (acceptable), 1.5-2.5 mm (borderline), and >2.5 mm (outliers). RESULTS: Overall, 81 (62.3 %) of the knees were free of outliers. The distal femur cut had the highest proportion of acceptable cut error with 209 of 260 total cuts acceptable (80.4 %). The tibial cuts had the lowest proportion of "acceptable" cuts (68.9 %). Tibial cuts had more outliers (33 of 260 cuts, 12.7 %) than the femur (39 of 520 cuts, 7.5 %) (p = 0.01). Pre-operative varus (n = 97) and valgus (n = 33) deformities demonstrated 7.7 % (45/482) and 13.6 % (27/198) of cuts which were outliers, respectively (p = 0.01). CONCLUSION: PSI showed only fair to moderate accuracy with 62.3 % of the knees presenting no outliers. The tibia cutting guide was less accurate than the femur. Specific attention is needed when cutting the tibia and in correction of valgus deformity. Moreover, intra-operative verifying measurements can provide feedback to the accuracy of the surgical plan. LEVEL OF EVIDENCE: IV, case series with no comparison group.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/cirurgia , Artroplastia do Joelho/métodos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Imageamento Tridimensional , Articulação do Joelho/diagnóstico por imagem , Cuidados Pré-Operatórios , Cirurgia Assistida por Computador , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Tomografia Computadorizada por Raios X
7.
J Arthroplasty ; 31(11): 2608-2616, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27178011

RESUMO

BACKGROUND: Venous thromboembolism (VTE) comprises pulmonary embolism and deep vein thrombosis and is a complication of particular concern in lower limb arthroplasty. In recent years, aspirin has emerged as a potential alternative thromboprophylactic agent, particularly after its acceptance as a recommended agent by the American College of Chest Physicians. Aspirin is favorable due to its relative cost-effectiveness and convenience compared to novel oral anticoagulants and warfarin. However, its efficacy since its inclusion in the American College of Chest Physicians guidelines remains unclear. The present systematic review aimed to establish the efficacy of aspirin in preventing VTE in total hip and knee arthroplasty. METHODS: Electronic searches were performed using 6 databases from up to June 2015, identifying all relevant studies. Data were extracted and meta-analyzed. RESULTS: Eleven relevant studies were identified for inclusion in the present meta-analysis. The overall rate of deep vein thrombosis and pulmonary embolism in both hip and knee arthroplasty was 1.2% and 0.6%, respectively. The rate of major bleeding was 0.3%. Pooled mortality rate was 0.2%. All findings demonstrated a high and significant degree of heterogeneity. CONCLUSION: Aspirin, both alone and in multimodal approaches to thromboprophylaxis, confers a low rate of VTE, with a low risk of major bleeding complications. However, the evidence for its use is limited by the low quality of studies and variation in dose in dosing regimes. Future randomized controlled trials should investigate the efficacy of aspirin, as well as the ideal dosing protocol for its use in thromboprophylaxis in arthroplasty.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Aspirina/uso terapêutico , Fibrinolíticos/uso terapêutico , Tromboembolia Venosa/prevenção & controle , Artroplastia de Quadril/mortalidade , Artroplastia do Joelho/mortalidade , Hemorragia/induzido quimicamente , Humanos , Extremidade Inferior/cirurgia , Embolia Pulmonar/etiologia , Embolia Pulmonar/prevenção & controle , Tromboembolia Venosa/etiologia , Trombose Venosa/etiologia , Trombose Venosa/prevenção & controle
8.
J Spine Surg ; 2(4): 334-337, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28097253

RESUMO

Correct component placement is of significant importance to ensure optimal outcomes in total hip arthroplasty (THA). Traditionally, the Lewinnek plane has been referenced as an adequate "safe zone", formed between the anterior superior iliac spines and public tubercles to optimize acetabular orientation. However, recent evidence shows that the positioning of this plane may vary due to the biomechanical relationship between the lumbar spine and hip. Therefore, the plane acquired intraoperatively may not accurately recreate the actual functional plane and acetabular orientation encountered outside of the intraoperative environment. This review summarizes the hip-spine relationship and its implications on THA.

9.
World J Orthop ; 6(10): 812-20, 2015 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-26601063

RESUMO

Squeaking is a well-recognized complication for hard-on-hard bearings. The nature of squeaking is not yet completely understood however it is considered a multifactorial phenomenon. Patient, implant, and surgical factors play a role in squeaking. It is believed that mechanisms damaging the fluid film lubrication in which these bearings function optimally have a critical role. Such mechanisms include edge loading, stripe wear, impingement, third body particles and ceramic fracture. The resonance of metallic parts can produce noise in the human audible range hence the implant metallurgic composition and design may play a role. Implant positioning can facilitate impingement and edge loading enhancing the occurrence of squeaking. The recent introduction of large heads (> 36 mm) 4(th) generation ceramic-on-ceramic bearing may accentuate the conditions facilitating noise formation; however the current literature is insufficient. Clinically, squeaking may manifest in extreme hip positions or during normal gait cycle however it is rarely associated with pain. Evaluations of patients with squeaking include clinical and radiographic assessments. Computer tomography is recommended as it can better reveal ceramic breakage and implant malposition. The treatments for most squeaking patients include reassurance and activity modification. However for some, noise can be a problem, requiring further surgical intervention. In the occurrence of ceramic fracture, implant failure, extreme components malposition, instability and impingement, surgery should be advised. This review will aim to discuss the current literature regarding squeaking.

10.
Orthop J Sports Med ; 2(11): 2325967114556257, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26535283

RESUMO

BACKGROUND: Injuries to the glenoid labrum frequently require repair with anchors. Placing anchor devices arthroscopically can be challenging, and anchor malpositioning can complicate surgical outcomes. PURPOSE: To determine the safe insertion range and optimal insertion angle of glenoid labral anchors at various positions on the glenoid rim and to establish surgical guidelines that minimize risk of anchor perforation. STUDY DESIGN: Descriptive laboratory study. METHODS: Three-dimensional computed tomography scans of 30 normal cadaveric specimens were obtained. A virtual model of a generic labral anchor was inserted into the rim of the glenoid at the clockface positions represented by 12:00, 1:30, 3:00, 4:30, 6:00, 7:30, 9:00, and 10:30. At each position, the safe insertion range was the maximal range measured, and the optimal insertion angle was identified as the angle between the bisector of the safe insertion range and the glenoid face. RESULTS: Progressing in the clockwise direction, beginning at the 12:00 position, the safe insertion ranges (mean ± SD ) were 55.9° ± 10.6°, 63.6° ± 17.6°, 47.7° ± 9.1°, 46.1° ± 8°, 73.9° ± 9.7°, 40.9° ± 6.5°, 40.4° ± 7.4°, and 39.9° ± 7.1°, respectively. The optimal insertion angles were 47.9° ± 7.6°, 53.1° ± 10.9°, 35.0° ± 4.4°, 42.4° ± 4.9°, 60.9° ± 8.4°, 36.6° ± 5.9°, 31.2° ± 4.9°, 34.8° ± 4.6°, respectively. CONCLUSION: Optimal insertion angles and safe insertion ranges varied significantly with respect to the position on the glenoid face. The safe insertion range and optimal insertion angle were found to be wider at the anterior glenoid as compared with the posterior glenoid. A posterolateral insertion angle was safer than an anterior insertion angle at the 10:30 position. CLINICAL RELEVANCE: Proper arthroscopic technique resulting in anchor insertion at the correct angle, depth, and location will prevent anchor-related glenohumeral complications such as glenoid perforation, cartilage damage, persistent pain, decreased range of motion, and failure of the reconstruction.

11.
J Arthroplasty ; 28(8): 1286-90, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23541870

RESUMO

Median 14-year follow-up (mean 11.8 years) of a cemented primary posterior cruciate-retaining total knee arthroplasty (TKA) utilizing the Press-Fit Condylar (PFC) Sigma design was evaluated in 77 patients (79 TKA). Follow-up assessment included implant survivorship, x-rays, Knee Society rating system, and clinical evaluation. Radiographic analysis demonstrated minor non-progressive osteolysis in 40% (10/25) knees. Two revisions, one for instability at 4 years and one for polyethylene wear at 10 years were performed. Survivorship of the PFC Sigma knee implant was 97% using revision for any reason and 100% using aseptic loosening as endpoints. The PFC Sigma had excellent survivorship at 14 years, the longest clinical follow-up reported.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Polietileno , Cuidados Pós-Operatórios , Desenho de Prótese , Radiografia , Fatores de Tempo , Resultado do Tratamento
12.
J Arthroplasty ; 28(7): 1212-7, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23538122

RESUMO

Metal-on-metal (MoM) bearings for total hip arthroplasty (THA) have come under scrutiny with reports of high failure rates. Clinical outcome studies with several commercially available MoM THA bearings remain unreported. We evaluated 78 consecutive MoM THAs from a single manufacturer in 68 patients. Sixty-six received cobalt-chrome (CoCr) monoblock and 12 received modular titanium acetabular cups with internal CoCr liners. Femoral components were titanium with modular necks. At average 2.1 years postoperatively, 12 THAs (15.4%) demonstrated aseptic failure (10 revisions, 2 revision recommended). All revised hips demonstrated capsular necrosis with positive histology reaction for aseptic lymphocytic vasculitis-associated lesions/adverse local tissue reactions. Prosthetic instability following revision surgery was relatively common. Female gender was a strong risk factor for failure, though smaller cups were not. Both monoblock and modular components fared poorly. Corrosion was frequently observed around the proximal and distal end of the modular femoral necks.


Assuntos
Artroplastia de Quadril/instrumentação , Reação a Corpo Estranho/epidemiologia , Prótese de Quadril , Metais , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Falha de Prótese , Idoso , Cromo , Cobalto , Corrosão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Fatores de Risco , Fatores Sexuais , Titânio
13.
Ann Rheum Dis ; 72(2): 271-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22872023

RESUMO

OBJECTIVES: To determine the histological patterns of posterior cruciate ligament (PCL) degeneration during aging and in relation to changes in articular cartilage and anterior cruciate ligament (ACL) across the entire adult age spectrum. METHODS: Human knee joints (n=120 from 65 donors) were processed within 72 h of postmortem. Articular cartilage surfaces were graded macroscopically. Each PCL was histologically evaluated for inflammation, mucinous changes, chondroid metaplasia, cystic changes and orientation of collagen fibres. The severity of PCL degeneration was classified as normal, mild, moderate or severe. PCL scores were compared to ACL and cartilage scores from the same knees. RESULTS: All knees had intact PCL. Histologically, 6% were normal, 76% showed mild, 12% moderate and 9% severe degeneration. Fibre disorientation was the most prevalent and severe change. Histological grades of PCL and ACL correlated, but significantly fewer PCL than ACL showed severe changes. There was a weaker correlation between aging and total histological PCL scores (R=0.26) compared to aging and ACL scores (R=0.42). ACL scores correlated with cartilage scores (R=0.54) while PCL scores increased with the severity of osteoarthritis from grades 0 to III but not between osteoarthritis grades III-IV (R=0.32). In knees with ruptured ACL, the PCL scores correlated with cartilage scores of the lateral compartment. CONCLUSIONS: PCL histopathological changes were less severe than in the ACL. PCL degeneration was associated with ACL and cartilage damage. The lack of correlation with age indicates independent pathways for PCL versus ACL degeneration.


Assuntos
Envelhecimento/patologia , Ligamento Cruzado Anterior/patologia , Cartilagem Articular/patologia , Articulação do Joelho/patologia , Osteoartrite/patologia , Ligamento Cruzado Posterior/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
14.
Clin Orthop Relat Res ; 471(1): 231-7, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22961315

RESUMO

BACKGROUND: Fresh osteochondral allograft transplantation is an increasingly common treatment option for chondral and osteochondral lesions in the knee, but the long-term outcome is unknown. QUESTIONS/PURPOSES: We determined (1) pain and function, (2) frequency and types of reoperations, (3) survivorship at a median of 13.5 years, and (4) predictors of osteochondral allograft failure in the distal femur. METHODS: We evaluated 122 patients (129 knees) who underwent osteochondral allograft transplantation of the femoral condyle. Mean age was 33 years and 53% were male. Clinical evaluation included the modified Merle d'Aubigné-Postel (18-point), IKDC, and Knee Society function (KS-F) scores. We defined graft failure as revision osteochondral allografting or conversion to arthroplasty. We determined whether patient characteristics or attributes of the graft influenced failure. Minimum followup was 2.4 years (median, 13.5 years); 91% had more than 10 years of followup. RESULTS: Mean modified Merle d'Aubigné-Postel score improved from 12.1 to 16, mean IKDC pain score from 7.0 to 3.8, mean IKDC function score from 3.4 to 7.2, and mean KS-F score from 65.6 to 82.5. Sixty-one knees (47%) underwent reoperations. Thirty-one knees (24%) failed at a mean of 7.2 years. Survivorship was 82% at 10 years, 74% at 15 years, and 66% at 20 years. Age of more than 30 years at time of surgery and having two or more previous surgeries for the operated knee were associated with allograft failure. CONCLUSIONS: Followup of femoral condyle osteochondral allografting demonstrated durable improvement in pain and function, with graft survivorship of 82% at 10 years.


Assuntos
Transplante Ósseo/métodos , Fêmur/cirurgia , Sobrevivência de Enxerto , Traumatismos do Joelho/cirurgia , Articulação do Joelho/cirurgia , Osteocondrite Dissecante/cirurgia , Adolescente , Adulto , Idoso , Cartilagem Articular/patologia , Cartilagem Articular/cirurgia , Feminino , Fêmur/patologia , Seguimentos , Humanos , Traumatismos do Joelho/patologia , Articulação do Joelho/patologia , Masculino , Pessoa de Meia-Idade , Osteocondrite Dissecante/patologia , Transplante Homólogo , Resultado do Tratamento
15.
J Arthroplasty ; 28(3): 474-8, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23142435

RESUMO

This study compares the incidence of venous thromboembolic event (VTE) in 55 patients (110 knees) undergoing simultaneous bilateral TKA with 287 patients (287 knees) undergoing unilateral TKA using a mobile compression device as monotherapy prophylaxis in both groups. All patients were clinically evaluated 3months after surgery with symptomatic confirmed VTE as an endpoint. Deep venous thrombosis (DVT) was documented by duplex ultrasound and pulmonary embolism (PE) was documented by spiral CT. The simultaneous bilateral TKA group had 6 VTEs (10.9%) with 2 PEs (3.6%). The unilateral TKA group had 9 VTEs (3.1%), and 0 PE. Patients undergoing simultaneous bilateral TKA yielded more than twice the rate of VTE compared with patients undergoing unilateral TKA using a mobile compression device as sole thromboprophylactic modality.


Assuntos
Artroplastia do Joelho/efeitos adversos , Dispositivos de Compressão Pneumática Intermitente , Tromboembolia Venosa/prevenção & controle , Idoso , Feminino , Humanos , Incidência , Masculino , Estudos Retrospectivos , Tromboembolia Venosa/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...